London Underground Section 12 Approved Cables
![]() |
![]() |
![]() |
![]() |
| H1000 Section 12 Approved | H124 Section 12 Approved | CCTV London Underground | London Underground Equipment Room |
Webro has been supplying LUL and their installation contractors for many years. H124 co-axial section 12 approved cable brings the very latest in watertight foam dieletric technology, robustness and flexibility. With BNC connectors manufactured to the correct dimensions you are assured of the optimum holding power and insertion loss with each connection.
| CABLE TYPE |
WEBRO P/No |
TYPE 2 |
TYPE 1 |
TYPE 3 |
APPLICATIONS | |
|
Type 2 - Section 12 |
Type 1 - Open Locations |
Section 12 Approved |
Open Locations | For External Use | ||
| COAXIAL | ||||||
| H124 Coax - 75 Ω | 62-YE00213 | 61-YE00361 | Approved | Yes | Yes | CCTV video transmission |
| H123 Rack Wiring - 75 Ω | - | 61-H123A02 | No | Yes | No | Rack Wiring in equipment rooms |
| H1000 Coax - 50 Ω | 62-YE00360 | 61-YE00364 | Approved | Yes | Yes | Platform announcement transmission |
| TRIAXIAL | ||||||
| H124 Triax - 75 Ω | 45124TRIAX-SLT-UV | - | Approved | No | No | Connect Project & CMS |
| FIBRE OPTIC | ||||||
| Fibre Breakout 4 fibres |
62-KDO210-4- 50/125-L |
61-KDO21 0-4-50/125 |
Approved | Yes | No | SMS, Visual Information Displays |
| Fibre Uni Distribution 4-8 fibres |
62-KDO30 0-8-50/125-L |
- | Approved | Yes | No | SMS, Visual Information Displays |
| Fibre Uni Distribution Upto 24 fibres | Call the sales team | - | Approved | No | No | SMS, Visual Information Displays |
| FIRE-X 950 - FIRE ALARM CABLES | ||||||
| 2 x 1.0mm | 62-F210U | 61-F210U-PE | Approved | Yes | Yes | Fire Alarm Systems |
| 2 x 1.5mm | 62-F215U | 61-F215U-PE | Approved | Yes | Yes | Fire Alarm Systems |
| 2 x 2.5mm | 62-F225U | 61-F225U-PE | Approved | Yes | Yes | Fire Alarm Systems |
| 7 x 1.0mm | 62-F710U | 61-F710U-PE | Approved | Yes | Yes | Fire Alarm Systems |
| MICC Fire Alarm Cable | Call the sales team | - | Approved | No | No | Fire Alarm Systems |
| CAT5E DATA CABLES | ||||||
| Cat5e 4pr UTP Data Cable | 62-YE00358 | 61-YE00362 | Approved | Yes | Yes | Ticket machines, DR, DT |
| Cat5e 4pr FTP Data Cable | 62-YE00359 | 61-YE00363 | Approved | Yes | Yes | Ticket machines, DR, DT |
| Cat5e 25pr UTP Data Cable | 62-YE00667 | - | Approved | No | Yes | Ticket machines, DR, DT |
| TELECOM G7623 | ||||||
| 1pr Telecom cable to G7623 | 62-2167NH | 61-2167AV | Approved | Yes | No | Telecommunication, PHP and DR |
| 3pr Telecom cable to G7623 | 62-2168NH | 61-2168AV | Approved | Yes | No | Telecommunication, PHP and DR |
All section 12 cables satisfy the mandatory requirements of London Underground and are fully approved.
BS ISO 4589 Pt 2 Flammability Temperature Index: > 280ºC BS EN 50268 Smoke Emission (3 metre cube) and E1042 A6 Clause 3 for Toxic Fume Emission.
In addition the coaxial cables satisfy CEI IEC 332 Cat C Vertical Ladder as bunched cables, with the char height on completion of the test less than 1.5m.
Features & Benefits - Section 12 approved cables generate extremely low smoke, are non-toxic, toxic gas and halogen free in the event of a fire situation. The sheath is also UV-resistant to reduce the ageing affects of sunlight should the cable be installed above ground.
Cables for use in LUL Metro System are sub divided in to 2 main types with a new third one depending upon the environment for use.
Type 1 - For use in open locations and above ground stations.
Type 2 - For use in tunnels or Underground locations and are suitable for installation in stations covered by Section 12 of the Fire Precautions (Sub-Surface Railway Stations) Regulations 1989.
Type 3 - External use and where standing water or ducts fill with water. Due to winning the contract to supply Atkins Rail with Cable & Connectors for the upgrade and refurbishment programme, Webro was asked to produce Fire Alarm cables for use in external environments and where rain and standing water might be present.
The Fire-X 950 Fire Alarm Cables are available in external sheaths, ideal for use in ducts where standing water may be present.
Webro continue to discuss with clients & develop new cables for this extreme of environments.